Date Description Inspector Results Comments
12/15/2017 FRAMING Approved IVRS - Inspection :*
12/14/2017 FRAMING Denied STIFFLEG TRUSS CONNECTION AT INTERIOR BEARING GARAGE WALL REQUIRES H2.5A'S AT EACH TRUCC CONNETION.