Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/16/2018 | PLUMBING - INTERMEDIATE | Approved | ||
| 05/08/2018 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE THE REQUIRED SHIELD PLATES THAT EXTEND 2 INCHES ABOVE THE SOLE PLATE AND 2 INCHES BELOW THE TOP PLATE. REFERENCE SECTION 305.6 2012 IPC. AS REQUESTED. 2- NOTE; THESE SHIELD PLATES ARE FOR THE SANITARY VENTS THAT ARE WITHIN 11/2 INCHES FROM THE EDGE OF THE PLATE. * |
|
| 05/02/2018 | PLUMBING - INTERMEDIATE | Denied | TOILET FLANGES MUST BE SECURED TO CONCRETE AND OR WOOD FLOOR SOLE PLATES AROUND PLIMBING HAVE TO BE SECURED AND REINFORCED CORRECTLY |
|
| 04/25/2018 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999 * |
|
| 01/22/2018 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1- EXPOSE THE CONNECTION TO THE KITCHEN SIND WASTE LINE. THIS LINE SHALL NOT CONNECT TO THE WATER CLOSET TRAP ARM. 2- REMOVE ALL P-TAPE AND PROVIDE APPROVED STRAPS. 3-CAN NOT POSITION THE CLEAN OUT TEE FOR THE CLOTHES WASHER ON A HORIZONTAL POSITION. 4- SHALL PROVIDE THE REQUIRED SHIELDED PLATES ON THE TOP AND SOLE PLATES. |