| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/14/2018 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 02/13/2018 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PAINT THE GAS PACK UINTS CONDENSATE DRAINS FOR PROTECTION. 2- SHALL PROVIDE 40 AMP FUESS FOR GAS PACKS ON THE ROOF. 3- SHALL REPAIR THE HOLES IN SANITARY VENTS THRU ROOF. 4- SHALL SECURE THE LIQUID TIGHT ELECTRICAL WHIPS TO THE EQUIPMENT. 5-SHALL PROVIDE TWO HOLE STRAPS ON GAS LINE ON ROOF. P-TAPE IS NOT APPROVED MATERIAL. 6- SHALL DISCHARGE THE CONDENSATE DRAIN TO THE SCUPPER, NOT THE SANITARY VENT. * |
|
| 02/12/2018 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL CAULK ALL PLUMBING FIXTURES. 2- SHALL PROVIDE THE TANK TYPE WATER CLOSET HANDLE TO BE LOCATED ON THE OPEN SIDE OF THE STALL. 3-SHALL PROVIDE A MINIMUM OF 6 INCHES OF DISCHARGE TUBE FROM THE CRITICAL LEVEL TO THE TOP OF THE URINAL ON THE FLUSHOMETER. 4- SHALL PROVIDE A WATTS 1022 IN LINE BACKFLOW PREVENTER FOR THE ICE MACHINE WATER SUPPLY. 5- SHALL PROVIDE A WATTS 007 BACKFLOW PREVENTER FOR THE BUFFET STEAM TABLE. 6- MENS ACCESSIBLE WATER CLOSET SHALL BE LOCATED 16 TO 18 INCHES OF CLEARANCE FROM SIDE WALL. 7- SHALL PROVIDE A ANZUL VALVE LOCATED SIGN ON CEILING. 8- SHALL PROVIDE A EXPANSION TANK AT THE WATER HEATER. 9- SHALL SEAL ALL EXTERIOR PENETRATIONS. 10- SHALL LOCATE THE TOWEL DISPENSER 48 INCHES FROM THE FLOOR LEVEL TO THE PAPER EXIT OF DISPENSER. 11- SHALL PROVIDE THE ACCESSIBLE SIGNAGE FOR MENS AND WOMENS RESTROOMS. 12- SHALL PERMANTE INSTALL THE BUILDING ADDRESS. 12 INSPECTION STOP! *LE TO BE LOCATED ON THE OPEN SIDE OF THE STALL |
|
| 02/05/2018 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- NOT READY FOR INSPECTION. 2- SHALL PAY A REINSPECTION FEE PROIR TO THE NEXT INSPECTION. NOTE; THE ENTIRE ENTERIOR OF BUILDGING HAD CONSTRUCTION DEBRI, CONTRACTOR WAS STILL WORKING ON INCOMPLETED WORK, NO ACCESS TO FIXTURES AND RECEPITALS. OWNER HAS BEEN WARNED ABOUT CALLING IN FOR INSPECTION WHEN WORK IS INCOMPLETE. * |