Permit: T17CM06565

Parcel: 122153860


Addresses:

3402 E SENECA ST

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
11/16/2017 ELECTRIC - INTERMEDIATE Approved
11/15/2017 ELECTRIC - INTERMEDIATE Denied 1. DISCONNECT REQUIRED AT ELECTRIC WATER HEATER.
2. GROUND ALL METAL BOXES.
3. MOVE PEX MINIMUM 12" FROM CAN LIGHT
10/27/2017 ELECTRIC - INTERMEDIATE Partial Approval RE-WIRE BATHROOM, SPLICED WIRES IN A CONCEALED J BOX
DISCONNECT REQUIRED FOR ELECTRIC WATER HEATER
GROUND ALL METAL BOXES
DRYER VENT
10/16/2017 ELECTRIC - INTERMEDIATE Partial Approval SECURE ALL ROMEX WITHIN 8" OF OUTLET.
ROMEX CAN ONLY BE BUNBELED FOR 2'.
PROVIDE A JBOX AT WIRE SPLICES.
FIRESTOP ALL HOLES IN TOP PLATES.
PROVIDE DOUBLE WALL VENTING FOR GAS APPLIANCES.
PROVIDE A DRYER VENT.
PROVIDE COMBUSTION AIR AT WATER HEATER.
PROVIDE BACKING AT CEILING BOXES.