Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2017 | ELECTRIC - INTERMEDIATE | Approved | ||
| 11/15/2017 | ELECTRIC - INTERMEDIATE | Denied | 1. DISCONNECT REQUIRED AT ELECTRIC WATER HEATER. 2. GROUND ALL METAL BOXES. 3. MOVE PEX MINIMUM 12" FROM CAN LIGHT |
|
| 10/27/2017 | ELECTRIC - INTERMEDIATE | Partial Approval | RE-WIRE BATHROOM, SPLICED WIRES IN A CONCEALED J BOX DISCONNECT REQUIRED FOR ELECTRIC WATER HEATER GROUND ALL METAL BOXES DRYER VENT |
|
| 10/16/2017 | ELECTRIC - INTERMEDIATE | Partial Approval | SECURE ALL ROMEX WITHIN 8" OF OUTLET. ROMEX CAN ONLY BE BUNBELED FOR 2'. PROVIDE A JBOX AT WIRE SPLICES. FIRESTOP ALL HOLES IN TOP PLATES. PROVIDE DOUBLE WALL VENTING FOR GAS APPLIANCES. PROVIDE A DRYER VENT. PROVIDE COMBUSTION AIR AT WATER HEATER. PROVIDE BACKING AT CEILING BOXES. |