Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 01/08/2018 |
PLUMBING - SEWER HCS CONNECT |
|
Approved |
|
| 01/05/2018 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
NEED TO INSPECT CITY CONNECTION |
| 12/05/2017 |
PLUMBING - SEWER HCS CONNECT |
|
Partial Approval |
OK TO BACKFILL/ LEAVE TRENCH OPEN AT CONNECTIONS |