Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T17CM06304
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/18/2017 | FRAMING | Approved | IVRS - Inspection :* | |
10/16/2017 | FRAMING | Denied | 1. FHA STRAP ALL ABS OVERBORES - NOT JUST BANG PLATES. 2. FHA STRAP DRYER VENT AT TOP PLATES. 3. NEED A/C DUCT CONNECTED IN LAUNDRY. 4. UP HALL BATH NEEDS GFI WITHIN 3' OF SINK. 5. SPLICE CUT RAT RUN AT PRIMARY CONDENSATE DRAIN LINE. 6. A/C LINES HANGING IN S.E. BEDROOM. 7. FINISH MESH AT SEVERAL ROOFS AND A/C LINE POP-OUT. 8. UFER NOT CONNECTED. |