Permit: T17CM06304

Parcel: 141094580


Addresses:

6425 E BOLDIN DR


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T17CM06304

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/18/2017 FRAMING Approved IVRS - Inspection :*
10/16/2017 FRAMING Denied 1. FHA STRAP ALL ABS OVERBORES - NOT JUST BANG PLATES.
2. FHA STRAP DRYER VENT AT TOP PLATES.
3. NEED A/C DUCT CONNECTED IN LAUNDRY.
4. UP HALL BATH NEEDS GFI WITHIN 3' OF SINK.
5. SPLICE CUT RAT RUN AT PRIMARY CONDENSATE DRAIN LINE.
6. A/C LINES HANGING IN S.E. BEDROOM.
7. FINISH MESH AT SEVERAL ROOFS AND A/C LINE POP-OUT.
8. UFER NOT CONNECTED.