Permit: T17CM06193

Parcel: 11106254A


Addresses:

2945 N EDITH BL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/29/2017 PLUMBING - FINAL Approved CLEAR GAS METER
08/18/2017 PLUMBING - FINAL Denied 1- SHALL BOND THE GAS LINE #6 GROUND CONDUCTOR.
2- SHALL REMOVE THE MECHANICAL TAPE AROUND THE DOUBLE WALL FLU VENT FOR THE WATER HEATER AND PROVIDE (3) SHEET METAL SCREWS PER JOINT AND ON THE DRAFT COLLAR.
3- SHALL REMOVE THE FLEX CONNECTORS ON THE WATER HEATER T & P DRAIN.
4- SHALL SEAL THE GAS LINE PENETRATION THRU THE EXTERIOR WALL BY METER.
5- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR.
6- SHALL CONNECT THE DRYER VENT.
7- SHALL PROVIDE COMBUSTION AIR VENTS FOR WATER HEATER.