Permit: T17CM06090

Parcel: 119041960


Addresses:

3562 S CLARK AV

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
03/16/2020 ELECTRIC - INTERMEDIATE Approved
12/21/2018 ELECTRIC - INTERMEDIATE Not ready for Inspection no wiring for water heater. Still need to use correct boxes or extensions on exterior boxes. Previously used box for a smoke alarm in middle bedroom cannot be covered up by sheet rock bring down to ceiling level and use as junction box. Still missing exterior receptacle by front door. Another failed inspection will result in a reinspection fee.
12/14/2018 ELECTRIC - INTERMEDIATE Not ready for Inspection repair Romex in master closet and staple within 6 inches of box. Need correct boxes or extensions on exterior boxes. Need fridge on dedicated circuit. Need exterior receptacle by front door. Need smoke alarm boxes is at correct heights. Smoke alarm in the middle bedroom too close to supply air. Another failed inspection may result in a reinspection fee.
10/04/2018 ELECTRIC - INTERMEDIATE Denied Verify 2:20 amp small appliance circuits kitchen counters

provide dedicated refrigerator Outlet secure home runs

nail protector throughout

seal top plate penetrations

stopped inspection too many items to list