Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/19/2017 | FRAMING | Approved | ||
| 10/17/2017 | FRAMING | Denied | 1. NEED FHA STRAPS AT 3" ABS OVERBORE IN GARAGE TOP PLATES AND IN KITCHEN. IN KITCHEN ONE, NAILING OFF THE OSB IN THE SOFFIT AREA WOULD SUFFICE. 2. STRAP ACCROSS 6X6S WHERE TOP PLATES DON'T OVERLAP. 3. RE-INSTALL FIRE BLOCK IN GARAGE N. WALL. 4. SCREW TOILET FLANGE TO SLAB IN POWDER ROOM. 5. MOVE PEX 12" FROM CAN LIGHT IN KITCHEN SOFFIT. 6. STRAP TOP PLATES ABOVE E. BEDROOM WINDOW WHERE NOT LAPPED 48". 7. PRESSURE UP HOT WATER LINES. 8. CUT ROOF OSB 1" FROM FLUE B VENT. |
|
| 10/16/2017 | FRAMING | Denied | MISSING FIRE BLOCKIING 2ND FLOOR CHASE, SOME ELECTRICAL HOLES IN TOP PLATE |