Permit: T17CM05686

Parcel: 11308296B

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/19/2017 FRAMING Approved
10/17/2017 FRAMING Denied 1. NEED FHA STRAPS AT 3" ABS OVERBORE IN GARAGE TOP PLATES AND IN KITCHEN. IN KITCHEN ONE, NAILING OFF THE OSB IN THE SOFFIT AREA WOULD SUFFICE.
2. STRAP ACCROSS 6X6S WHERE TOP PLATES DON'T OVERLAP.
3. RE-INSTALL FIRE BLOCK IN GARAGE N. WALL.
4. SCREW TOILET FLANGE TO SLAB IN POWDER ROOM.
5. MOVE PEX 12" FROM CAN LIGHT IN KITCHEN SOFFIT.
6. STRAP TOP PLATES ABOVE E. BEDROOM WINDOW WHERE NOT LAPPED 48".
7. PRESSURE UP HOT WATER LINES.
8. CUT ROOF OSB 1" FROM FLUE B VENT.
10/16/2017 FRAMING Denied MISSING FIRE BLOCKIING 2ND FLOOR CHASE, SOME ELECTRICAL HOLES IN TOP PLATE