Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T17CM05680

Parcel: 205946520

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T17CM05680

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
09/15/2017 PLUMBING - ROUGH, SOIL Approved
08/04/2017 PLUMBING - ROUGH, SOIL Partial Approval Tub grey not installed
08/02/2017 PLUMBING - ROUGH, SOIL Denied Backpitch at 1/8th bend. Support trap arms.
Grey water is not installed as shown on plan.
Your City Approved plan detail clearly shows the Tub drain pipe to exit the building then turn back into the building before connecting to building drain. The plan also shows a Grey water Washer box piped to an exterior wall terminating above grade.
Your approved plan clearly shows a KItchen sink vent. Install as shown or provide documentation from your Engineer of record for this project for all changes.
08/01/2017 PLUMBING - ROUGH, SOIL Denied Piping installed below grade shall be continuously supported by compacted earth or sand or by supported sleeving. Isolate piping from rebar.
Grey water is not installed as shown on plan.
Correct slope.
Expose HCS