Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T17CM05659
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/02/2017 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
10/31/2017 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE A WATER TEST ON THE DWV SYSTEM. 2-SHALL SECURE THE CLOSET FLANGES TO THE FLOOR. 3- GAS PRESSURE TEST AT ZERO PSI. 4- SHALL PROVIDE (3) SIDED BLOCKING FOR AIR VENT IN KITCHEN. 5- GROUND BOND CLAMP MISSING ON GAS LINE. 6- HORIZONTAL VENT SHALL BE 6 INCHES ABOVE THE FLOOD LEVEL RIM OF OF SHOWER AND WATER CLOSET. * |
|
10/30/2017 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |