Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T17CM05497

Parcel: 140240300

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T17CM05497

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
04/04/2019 EXT METAL CLIPS/EXT SHEATHING Approved Exterior Osb sheathing ok. Told owner to nail off under the windows before finishing.
03/13/2019 EXT METAL CLIPS/EXT SHEATHING Denied Expose H25 clips per details 1/2&2/2 at floor framing plan
Expose st18 straps per detail 3/3
Expose h25 clips per details 1/3&2/3
Approved plan calls for 2 x 6 @ 16” on center roof rafters installed at 24 inches on center submit as built or build to plan.
plan
Expose bearing wall at existing mobile home to ensure it is not connected to home
Stopped inspection