Permit: T17CM05287

Parcel: 127122680


Addresses:

5759 E BROADWAY BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T17CM05287

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/06/2018 PLUMBING - FINAL Approved
04/04/2018 PLUMBING - FINAL Partial Approval REVIEW OF WATER CHLORINATION REPORT COMPLETED
04/04/2018 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE A 1022 IN LINE BACKFLOW PREVENTERS FOR ALL ICE MAKERS AND TEA DISPENSER MACHINE.
2- SHALL PROVIDE A SAFTEY CABLE FOR THE OVEN.
3- SHALL REMOVE THE FERNCO COUPLING ON THE TRIPPLE COMPARTMENT SINK INDIRECT WASTE LINE.
4- SHALL PROVIDE VACUUM BREAKERS ON ALL EXTERIOR HOSE BIBS.
5- SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT ON THE WATER HEATER FLU VENT AND DRAFT COLLAR.
6-SHALL PROVIDE A MINIMUM OF 1 INCH ANULAR SPACE AROUND THE WATER HEATER FLU VENT THU THE CEILING.
7- SHALL LOCATE THE ACCESSIBLE RESTROOMS MIRROR 40 INCHES FROM FLOOR LEVEL TO THE REFLECTION OF THE MIRROR.
8- SHALL PROVIDE A PERMANATE LABLE SHOWING THE ANZUL VALVE LOCATION ON THE CEILING TILE.


*
10/26/2017 PLUMBING - FINAL Prior to Final Inspectn WATER CHLORINATION REPORT REQUIRED