Permit: T17CM05052

Parcel: 114516970


Addresses:

8738 E HONEYBEAR PL

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
07/27/2017 MECHANICAL - FINAL Approved
07/25/2017 MECHANICAL - FINAL Denied DOUBLE WALL VENT REQUIRES MIN. 1' FROM COMBUSTIBLES. THIS INCLUDES THE TAR TAPE AND DOOR JAMB.
THE 1ST FITTING AT FURNACE IS UPSIDE DOWN.
YOU CANNOT USE A SINGLE WALL FITTING TO SPLICE 2 PIECES OF DOUBLE WALL VENTS.
AMERIVENT AND DURA VENT DO NOT HAVE MATCHING ENDS.
07/12/2017 MECHANICAL - FINAL Partial Approval CORRECTIONS HAVE NOT BEEN MADE.
07/07/2017 MECHANICAL - FINAL Partial Approval WEST UNIT PROVIDE 6" CLEARANCE AT ARMAFLEX AND VENT CONNECTOR. OK TO USE FIBERGLASS PIPE INSULATION.
TIGHTEN ROMEX CONNECTOR.