Permit: T17CM04954

Parcel: 111080640

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/01/2017 FRAMING Approved
07/24/2017 FRAMING Partial Approval EXTERIOR WALLS IN CLOSET ALSONEED TREATED WOOD. BEDROOMS ARE OK.
ELEC. WIRE NEED TO BE SECURED AT THE BOX AND PROVIDE CONNECTORS AT BOXES.
07/20/2017 FRAMING Denied PROVIDE ARC FAULT BREAKERS AND TAMPER PROOF RECEPTACLES.
PROVIDE ROMEX CONNECTORS AT JBOXES IN ATTIC.
PROVIDE TREATED WOOD AT EXTERIOR BOTTOM PLATES.
EXPOSE ELEC. AT 2 BOXES IN EACH ROOM.
PROVIDE 3 PRONG RECEPTACLES.PROVIDE GROUNDING JUMPERS AT ALL METAL BOXES.