Permit: T17CM04915

Parcel: 205946050

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T17CM04915

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
08/03/2017 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
08/02/2017 PLUMBING - ROUGH, SOIL Denied Support trap arms.
Grey water is not installed as shown on plan.
Your City Approved plan detail clearly shows the Tub drain pipe to exit the building then turn back into the building before connecting to building drain. The plan also shows a Grey water Washer box piped to an exterior wall terminating above grade.
Your approved plan clearly shows a KItchen sink vent. Install as shown or provide documentation from your Engineer of record for this project for all changes.
08/02/2017 PLUMBING - ROUGH, SOIL Denied
08/01/2017 PLUMBING - ROUGH, SOIL Denied Piping installed below grade shall be continuously supported by compacted earth or sand or by supported sleeving. Isolate piping from rebar.
Grey water is not installed as shown on plan.
note Kitchen sik VTR


*