Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/03/2017 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 08/02/2017 | PLUMBING - ROUGH, SOIL | Denied | Support trap arms. Grey water is not installed as shown on plan. Your City Approved plan detail clearly shows the Tub drain pipe to exit the building then turn back into the building before connecting to building drain. The plan also shows a Grey water Washer box piped to an exterior wall terminating above grade. Your approved plan clearly shows a KItchen sink vent. Install as shown or provide documentation from your Engineer of record for this project for all changes. |
|
| 08/02/2017 | PLUMBING - ROUGH, SOIL | Denied | ||
| 08/01/2017 | PLUMBING - ROUGH, SOIL | Denied | Piping installed below grade shall be continuously supported by compacted earth or sand or by supported sleeving. Isolate piping from rebar. Grey water is not installed as shown on plan. note Kitchen sik VTR * |