Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T17CM04788

Parcel: 134210550


Addresses:

223 S BIRCH PL

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
08/01/2018 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
07/31/2018 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection Tape vertical rebar standoffs that penetrate the dirt and hold the horizontal footing rebar/steel in the forms.
07/26/2018 EXCAVATION/LAYOUT REBAR & ZON Correction Required Sleeve ABS DWV parallel through footing with a solid materioal that will not compromise poured footing strength. Termite spray required 24 hours before you pour the monolithic slab and footings. Tape rebar standoffs pounded into dirt to prevent rusting within the soil. Water pipe shall have clearance from horizontal footing rebar, cement and aggregate must have encapsulating and flow space to not create a void.
07/23/2018 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection