Inspection History: FRAMING
Permit Number - T17CM04695
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/21/2017 | FRAMING | Approved | IVRS - Inspection :* | |
09/15/2017 | FRAMING | Denied | 1- NO ACCESS TO UNIT 227,DOOR WAS LOCKED. 2- SHALL PROVIDE A BRASS PLUG FOR UNUSED DRAIN, PLASTIC PLUG NOT APPROVED FOR CAST IRON. 3- SHALL NOT REDUCE THE LAVATORY DRAIN FROM 2 INCH TO 1 1/2 INCH. 3- SHALL LOCATE THE HORIZONTAL REVENT A MINIMUM OF 6 INCHES ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE, 5- SHALL PROVIDE MISSION SPECIALTY COUPLING WHEN CON NECTING DISSIMULAR MATERIALS ON THE SANITARY WASTE AND VENT SYSTEM. |
|
09/11/2017 | FRAMING | Denied | 1- SEE NOTE #1. 2- LAVATORY TRAP ARM DOES NOT MEET CODE. 3- SHALL REMOVE ALL SWITCHES AND OUTLETS IN ORDER TO VERIFY THAT ALL METAL BOXES HAVE BEEN GROUNDED. 4- SHALL PROVIDE A CONDUCTOR STAPLE WITHIN 6 INCHES OF THE GANG BOX ON IN HALLWAY. |
|
09/07/2017 | FRAMING | Cancelled | IVRS - RI canceled | |
07/26/2017 | FRAMING | Denied | 1- SHALL SEAL ALL TOP PLATE PENETRATIONS WITH FIRE RATED CAULK OR FOAM. 2- SHALL REPAIR ALL TEARS ON HVAC FLEX DUCTS. 3- SHALL SECURE THE 1ST FLOOR BATHROOM LIGHT BOX. |