Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T17CM04681

Parcel: 126070470


Addresses:

226 N ROJEN CT

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
06/20/2017 PLUMBING - FINAL Approved OK RES. GAS
CALLED SWG
06/19/2017 PLUMBING - FINAL Denied 1- SHALL PROVIDE THE APPROVED DRAWING FOR GAS SYSTEM AND PERMIT ON SITE.
2- SHALL PROVIDE A WATER HEATER DRIP PAN UNDER THE WATER HEATER AND EXTEND AND TERMINATE THE T & p DRAIN INTO THE PAN AND CAP OFF THE PAN DRAIN OUTLET.
3- SHALL BOND THE GAS LINE.
4- SHALL CLEAN ALL DEBRI BEHIND AND AROUND THE WATER HEATER.
5- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR.
06/16/2017 PLUMBING - FINAL Denied 1- WORK IS INCOMPLETE AT THE TIME OF INSPECTION REQUEST.