Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T17CM04612
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/23/2019 | FRAMING | Approved | ||
| 03/27/2019 | FRAMING | Partial Approval | Maintenance restroom in basement OK to cover interior walls. Plumbing re-vent on north wall needs continuous grade for gravity venting. | |
| 02/04/2019 | FRAMING | Partial Approval | Building #3, leasing area, Building #4 interior framing. | |
| 01/30/2019 | FRAMING | Partial Approval | Building #3, Leasing area; Building #4, interior framing | |
| 11/02/2018 | FRAMING | Partial Approval | Building #1, Level 2 deck. Ok to place wall framing (reopenED 1035 to read partial-PER JBURGE) |
|
| 10/31/2018 | FRAMING | Partial Approval | Building #1, Level #1: Rooms and corridor. | |
| 10/23/2018 | FRAMING | Partial Approval | Building #1, Level #2 deck; nailing and straps. Ok to proceed with interior framing | |
| 10/05/2018 | FRAMING | Partial Approval | Building #2, Level #4; Exterior framing. Ok to cover. | |
| 09/20/2018 | FRAMING | Not ready for Inspection | WORK INCOMPLETE. RESCHEDULED FOR. 9.21. | |
| 09/19/2018 | FRAMING | Partial Approval | BUILDING #2, EXTERIOR, LEVEL #4: OK TO COVER PROGRESS AREAS, | |
| 09/18/2018 | FRAMING | Cancelled | ||
| 09/13/2018 | FRAMING | Partial Approval | BUILDING #3, LEASING OFFICE AREA - METAL FRAMING. | |
| 08/30/2018 | FRAMING | Partial Approval | BLDG 2 LEVEL 3 OK TO COVER EXTERIOR WALLS | |
| 08/17/2018 | FRAMING | Partial Approval | BUILDING #2; EXTERIOR WALLS AT LEVEL #2 - OK TO COVER PROGRESS AREAS. BUILDING #3, LEVEL #4 INTERIOR FRAMING. | |
| 08/16/2018 | FRAMING | Partial Approval | BUILDING #2, LEVEL #1: EXTERIOR METAL FRAMING. OK TO COVER PROGRESS AREAS. | |
| 08/14/2018 | FRAMING | Partial Approval | BUILDING #3, LEVEL #2. | |
| 07/31/2018 | FRAMING | Partial Approval | BUILDING #3, LEVEL #4, SUB-DECKING - OK TO FRAME WALLS. | |
| 07/30/2018 | FRAMING | Partial Approval | BUILDING #3, LEVEL #2, FRAMING IS COMPLETE. | |
| 07/27/2018 | FRAMING | Cancelled | CONTRACTOR CANCELLED. | |
| 07/25/2018 | FRAMING | Cancelled | CONTRACTOR CANCELLED. WORK INCOMPLETE. | |
| 07/13/2018 | FRAMING | Partial Approval | BUILDING #3, LEVEL #1, CLIPS AND STRAPS ARE IN PLACE. | |
| 07/12/2018 | FRAMING | Cancelled | CONTRACTOR CANCELLED. | |
| 07/06/2018 | FRAMING | Not ready for Inspection | WILL RESCHEDULE FOR 9 JULY 2018 | |
| 06/13/2018 | FRAMING | Partial Approval | BUILDING #1, LEVEL #4 DECK; NAILED AND STRAPPED. OK TO COVER. | |
| 06/08/2018 | FRAMING | Partial Approval | BUILDING #1, LEVEL #2, INTERIOR STRAPS AND CLIPS. | |
| 05/31/2018 | FRAMING | Partial Approval | BUILDING #1, LEVEL 3 DECKING - (NORTH AND SOUTH) | |
| 05/25/2018 | FRAMING | Partial Approval | BUILDING #1, LEVEWL #1: INTERIOR STRAPS AND CLIPS; SHEAR WALLS NAILING AND CLIPS. | |
| 05/21/2018 | FRAMING | Partial Approval | BUILDING #1, LEVEL #2 DECK, SOUTH PORTION - OK TO SET WALL FRAMING. | |
| 05/15/2018 | FRAMING | Partial Approval | BUILDING #1, EXTERIOR SHEATHING (FIRST LAYER)*; LEVEL #2 DECK - NORTH HALF. *EXTERIOR SHEATHING: POSSIBLE ADDITION OF 1/4" VANEER SHEATHING TO MAKE EXTERIOR WALLS 7/16" AS PER PLAN. AWAITING APPROVAL FROM ARCHITECT. |