Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2017 | PLUMBING - GAS RECONNECT | Approved | ||
| 11/22/2017 | PLUMBING - GAS RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999 * |
|
| 11/06/2017 | PLUMBING - GAS RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- THE GAS LINE DROP SUPPLY TO THE WATER HEATER AND FURNACE IN FRONT OF THE WATER HEATER AND WILL NOT ALLOW ACCESS FOR REMOVAL AND SERVICE. REFERENCE M1305.1 IRC. 2- THE SEDIMENT TRAP FOR THE FURNACE IS NOT LOCATED IN THE CORRECT LOCATION. THE SEDIMENT TRAP SHALL BE LOCATED DOWN STREAM OF THE SHUT OFF VALVE. 3- SHALL PROVIDE THE REQUIRED COMBUSTION AIR FOR THE FURNACE AND WATER HEATER. 4- RETEST THE GAS LINE SYSTEM. * |
|
| 10/16/2017 | PLUMBING - GAS RECONNECT | Denied | IVRS - Inspection : There is no access to the site.| 920 * |