Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T17CM04530
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/28/2017 | PLUMBING - ROUGH, SOIL | Approved | OK TO POUR FOOTINGS AND SLAB. | |
08/25/2017 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
08/23/2017 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | CANCELED BY CONTRACTOR. | |
08/11/2017 | PLUMBING - ROUGH, SOIL | Denied | DIRT STILL SOAKING WET. EXPOSE ALL JOINTS OF FITTINGS. FILL 10' TEST ALL THE WAY TO TOP. WET DIRT AND LOW WATER LEVEL INDICATES A LEAK. |
|
08/10/2017 | PLUMBING - ROUGH, SOIL | Denied | DWV NOT HOLDING TEST. TRENCH FILLED WITH WATER. NEED DRY DIRT AT ALL FITTINGS. | |
08/02/2017 | PLUMBING - ROUGH, SOIL | Denied | PROVIDE APPROVED PLANS AND PERMIT. |