Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2017 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/20/2017 | FRAMING | Denied | Anchore bolts are loose, have been cut and dust has not been removed. All opennings nin electrical boxes shall be sealed; main panel, exterior outlets require romex connector. NEC 300.21 Expose UFER Support flex ducts Refee warning * |
|
| 09/18/2017 | FRAMING | Not ready for Inspection | complete all noted corrections | |
| 09/14/2017 | FRAMING | Denied | dwv and shower pans are not under test. Repair top plates at plumbing pipes on exterior walls. Seal floor penetrations and hole in electrical panel. Tighten loose anchor bolts, correct torn ducts, isolate pex from gang nailers, provide freeze protection in any uninsulated areas. Install romex connector in exterior recepticle box. Locate SDs 3 feet from air vents. Ufer? |