Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T17CM04308

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
08/28/2017 PLUMBING - INTERMEDIATE Approved
08/25/2017 PLUMBING - INTERMEDIATE Denied 1- SEE NOTE #1 AS REQUESTED FROM PREVIOUS INSPECTION ON 08/23/17.
2- RETEST SYSTEM.
08/23/2017 PLUMBING - INTERMEDIATE Denied 1- SHALL LOCATE THE HORIZONTAL VENT FOR THE SECOND FLOOR TUB A MINIMUM OF 6 INCHES ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE.
2- SHALL SECURE THE WATER LINES EVERY 32 INCHES HORIZONTALLY.
3- SHALL PROVIDE A SAFTEY PLATE FOR ABS AT STAIRWELL.