Permit: T17CM04013

Parcel: 137293150


Addresses:

1630 W DEACON DR

Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
08/22/2017 ELECTRIC - INTERMEDIATE Approved
08/08/2017 ELECTRIC - INTERMEDIATE Denied ILLEGAL SPLICES EXPOSED IN ATTIC AT EXHAUST FAN
OPEN JUNCTION BOXES IN ATTIC
OPEN WIRING IN ATTIC
07/13/2017 ELECTRIC - INTERMEDIATE Denied SECURE ROMEX 8" FROM BOXES
JUNCTION BOX MUST BE ACCESSIBLE
WIRING INSULATION TO TERMINATE MIN 1/4" INTO APPROVED BOXES THROUGHOUT
NAIL PROTECT PUMBING
HARD DUCT DRYER VENT
06/30/2017 ELECTRIC - INTERMEDIATE Denied MISSING EXHAUST FAN
EXPOSEALLWORK FOR INSPECTION
HAMMER ARRESTORS LAUNDRY