Permit: T17CM03998

Parcel: 122184080


Addresses:

3543 E BELLEVUE ST

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
07/27/2017 MECHANICAL - INTERMEDIATE Approved OK FOR INSULATION AND SHEET ROCK.
07/20/2017 MECHANICAL - INTERMEDIATE Partial Approval FINISH CONDENSATE DRAIN LINES.
SECURE EX. FAN DUCTS TO FAN. TERMINATE THROUGH ROOF.
REVISE PLANS TO SHOW ALL MINI SPLIT UNITS.
07/19/2017 MECHANICAL - INTERMEDIATE Partial Approval CONDENSATE CANNOT BE REDUCED FROM OUTLET SIZE ON UNIT. 1/2" I.D. DRAIN LINE NOT ADEQUATE.
INSTALL EXHAUST FANS.
07/10/2017 MECHANICAL - INTERMEDIATE Not ready for Inspection INSTALL A/C DUCTWORK PER PLANS ALONG WITH LINE SETS AND DRAIN FOR MINI SPLIT, AND BATHROOM EXHAUST FANS.