Permit: T17CM03904

Parcel: 125160680

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/20/2017 PLUMBING - ROUGH, SOIL Approved OK TO BACKFILL DWV.
06/16/2017 PLUMBING - ROUGH, SOIL Denied 1- SHALL PROVIDE A SPECIALTY MISSION COUPLING ON AOUTOMATIC WASHER VENT CONNECTION.
2- SHALL MINIMUM OF TWO TIMES THE PIPE DIAMETER FOR THE AUTOMATIC WASHER TRAP ARM.
3- SHALL MAKE A PROPER SILLPHOS JOINT UNDER THE SLAB ON THE 1/2" COPPER SUPPLY CONNECTIONS.
4- SHALL PROVIDE AN APPROVED METHOD OF SUPPORT AND STRAPPING ON THE WASTE AND SOIL LINES AT GUEST SUITE BATHROOM.
5- SHALL LOCATE THE HORIZONTAL VENT FOR THE SHOWER WASTE LINE A MINIMUM 6" ABOVE THE FLOOD LEVEL RIM OF THE FIXTURE.
NOTE; OKAY TO COVER THE P.O.C. OF KITCHEN WASTE BRANCH LINE.