Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T17CM03899
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/12/2017 | PLUMBING - SEWER HCS CONNECT | Approved | ||
06/09/2017 | PLUMBING - SEWER HCS CONNECT | Denied | correct flat spot, compact dirt under pipe in over excavated trench failure to comply may result in refee * |
|
06/08/2017 | PLUMBING - SEWER HCS CONNECT | Denied | R2604.1 Bottom of trench shall provide continuous and load bearing support. Over excavated trenching shall be brought to grade with clean compactible fill R2605.1 Below ground piping shall be supported on a firm bed for it's entire length. 1. P2609.2 all materials used shall be installed in strict accord with it's listing Pipe supports shall be listed for such use and shall not cut or abraid support sewer courtesy inspection for Jay |
|
06/07/2017 | PLUMBING - SEWER HCS CONNECT | Denied | support sewer courtesy inspection for Jay |