Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2017 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 10/02/2017 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999 1- SHALL PROVIDE A P-TRAP FOR ALL INDIRECT WASTE PIPING THAT EXCEEDS 30 INCHES HORIZONTALLY OR 54 INCHES IN TOTAL DEVELOPED LENGTH. REFERENCE SECTION 802.2 IPC. 2- SHALL EXTEND AND TERMINATE ALL INDIRECT WASTE PIPING TO DISCHARGE PROPERLY INTO THE THE FLOOR SINK. 3- SHALL SECURE ALL WASTE PIPING EVERY 4 FEET AND CHANGES OF DIRECTION. 4 SHALL PROVIDE SAFETY CABLES FOR ALL GAS APPLIANCES THAT HAVE CASTERS. 5- SHALL PROVIDE A TEST AND CERTIFICATION FOR THE CARBONATED SODA DISPENSER BACKFLOW PREVENTER. * |