Permit: T17CM03789

Parcel: 10922005L

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T17CM03789

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/04/2019 FRAMING Approved Work is covered; no visible violations.
05/21/2019 FRAMING Partial Approval All but screws in RC channel.
05/17/2019 FRAMING Denied Work not being completed, another failed inspection will result in a reinspection fee.
05/17/2019 FRAMING Denied Work not being completed, another failed inspection will result in a reinspection fee.
05/15/2019 FRAMING Denied Fire stop above ceiling broken or not properly installed or sealed, wiring not properly sealed or nail plated, plumbing not on test, sealed through penetrations, mechanical ducts pinched off, boot box is not properly framed in, condensate vent to be above drain pan, exhaust duct not completed RC channel not to be hung with sheet rock screws, inspections stopped at this time too many items to list, this is not a Complete list.
05/08/2019 FRAMING Correction Required 1-Need to patch drywall hole cut out above ceiling in kitchen and several holes around AC lines near West end (no unit numbers marked to identify).
05/03/2019 FRAMING Partial Approval Third floor.
12/19/2018 FRAMING Partial Approval Porch decking on second floor.
12/12/2018 FRAMING Partial Approval Second floor deck for main building only; porches not ready
10/16/2018 FRAMING Partial Approval First floor deck and trusses OK
10/12/2018 FRAMING Cancelled Too slippery with rain to perform safe inspection