Permit: T17CM03784

Parcel: 10922005L

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T17CM03784

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
01/04/2019 PLUMBING - ROUGH, SOIL Approved roof drain systems
04/27/2018 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1- ALL CORRECTIONS HAVE BEEN MADE.
2- NOTE; THIS INSPECTION IS FOR THE FIRST FLOOR UNDERGROUNG PLUMBING ONLY. OKAY TOT COVER.
04/25/2018 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL LOCATE THE OUTLET OF THE VENTS FOR THE WATER CLOSETS ABOVE THE CENTER LINE OF THE SOIL LINE.
2- SHALL PROVIDE A MINIMUM DISTANCE OF TWO TIMES THE PIPE SIZE FOR THE MOP SINK TRAP ARM.
3- RETEST THE SYSTEM.


*