Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T17CM03737
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/28/2017 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
05/13/2017 | ELECTRIC - RECONNECT | Denied | 1) GFCI receptacles required above kitchen counters, vanities in bathrooms and above sink in garage 2) Weathertight receptacle cover needs replacement or reconnection on patio - GFCI receptacle required 3) Provide receptacle cover plates where missing 4) Provide breaker blanks at service where missing 5) Provide permanent address label at service panel |