Permit: T17CM03699

Parcel: 122152620


Addresses:

2160 N RITA AV

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
05/15/2017 PLUMBING - GAS PRESSURE TEST Approved
05/11/2017 PLUMBING - GAS PRESSURE TEST Denied 1- SHALL PROVIDE A WATER HEATER DRIP PAN AND EXTEND THE T & p DRAIN INTO THE PAN AND CAP OFF THE OUTLET.
2- SHALL BOND THE GAS LINE.
3- SHALL EXTEND THE FURNACE AND WATER HEATER FLU VENT AND TERMINATE IT 3'-0" ABOVE THE COOLER.
4- SHALL PROVIDE A SEDIMENT TRAP FOR THE WATER HEATER.
5- SHALL PROVIDE THE APPROVED DRAWING AND THE PERMIT ON SITE AT THE TIME OF INSPECTION.
6- SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT ON THE FURNACE FLU VENT.
7- SHALL PROVIDE THE REQUIRED TEST GAGE 15 LBS MAX.