Permit: T17CM03374

Parcel: 127122650


Addresses:

5721 E BROADWAY BL


Inspection Status: Approved

Inspection History: SHEET ROCK NAILING

Permit Number - T17CM03374

Inspection Description - SHEET ROCK NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
10/30/2017 SHEET ROCK NAILING Approved
10/25/2017 SHEET ROCK NAILING Partial Approval IVRS - Inspection :*
10/23/2017 SHEET ROCK NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL PROVIDE AN AIR PRESSURE TEST ON ENTIRE SYSTEM.
2- SHALL PROVIDE THE GAS SLEEVING AND VENT OPENING TERMINATION TO A LOW LOCATION WHERE A LEAK COILD BE DETECTED. REFERENCE 408.8.1 2012 IFGC.
3- SHALL REMOVE THE JIM CAPS ON THE PIPE SLEEVE ENDS AND PROVIDE A PERM. CAP THEN SEAL THE PENETRATION ON THE CAP.


*