Permit: T17CM03248

Parcel: 133320950


Addresses:

9032 E 5TH ST


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T17CM03248

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
05/08/2017 PLUMBING - FINAL Approved CLEAR GAS METER.
05/03/2017 PLUMBING - FINAL Denied 1- SHALL SCRAPE THE PAINT OFF OF THE GAS LINE TO PROVIDE A POSITIVE BOND CONTACT FROM THE GROUND CLAMP TO THE PIPE.
2- SEE NOTE # 3 AS REQUESTED.
04/27/2017 PLUMBING - FINAL Partial Approval 1- GAS PRESSURE TEST PROVIDED.
2- UNDERGROUNG POLYETHELYNE GAS LINE UNDER GROUND IS OKAY,TRACER WIRE PROVIDED.
3- NOTE;
1- WATER HEATER FLU VENT HAS A OPEN GAP IN VENT AND REQUIRES THAT ALL FLU VENT JOINTS TO BE SECURED WITH (3) SHEET METAL SCREWS PER JOINT.
2- SHALL BOND THE GAS LINE.
3- WATER HEATER T & p DRAIN IS UNDERSIZED AND SHALL TERMINATE INTO THE DRIP PAN.
4- SHALL PROVIDE HARD PIPE THROUGH THE FURNACE HOUSING THEN CONNECT THE FLEX CONNECTOR.