Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T17CM03004
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/26/2017 | PLUMBING - ROUGH, SOIL | Approved | ||
| 06/23/2017 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | 1- DWV WATER TEST IS NOT READY FOR INSPECTION. | |
| 06/21/2017 | PLUMBING - ROUGH, SOIL | Partial Approval | 1- DWV WATER TEST PROVIDED. 2- THIS INSPECTION IS FOR UNDERGROUND BLDG. SOIL AND WASTE LINES LOCATED AT THE WEST SIDE OF BUILDING AS NOTED ON PLAN. |
|
| 06/20/2017 | PLUMBING - ROUGH, SOIL | Denied | WATER LEAKING AT 3" ELBOW. HAVE DRY SOIL AT RISERS. |
|
| 06/15/2017 | PLUMBING - ROUGH, SOIL | Partial Approval | 1- SHALL PROVIDE TRAFFIC RATED CLEAN OUT COVERS IN THE ALLEY WAY. | |
| 06/13/2017 | PLUMBING - ROUGH, SOIL | Denied | 1- SHALL PROVIDE DUCTILE IRON PIPE WHEN THERE IS LESS THAN 12 INCHES OF SEPARATION BETWEEN THE CITY WATER MAIN AND THE BLDG. SEWERS. THYE DUCTILE IRON PIPE SHALL EXTEND 5 FEET OUT FROM BOTH SIDES OF THE CITY WATER MAIN. 2- SHALL PROVIDE THIS APPLICATION FOR BOTH BLDG. SEWERS. |