Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T17CM02530

Parcel: 13815014G


Addresses:

434 W LERDO RD 03


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T17CM02530

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
12/13/2017 REINFORCED MASONRY PRE-GROUT Approved
12/06/2017 REINFORCED MASONRY PRE-GROUT Partial Approval SOUTH COLUMNS 1 AND 4 4TH LIFT ONLY
SOUTH COLUMNS 2 AND 3 2ND LIFT ONLY
12/04/2017 REINFORCED MASONRY PRE-GROUT Partial Approval EXCEPT VENEER COLUMNS
1ST LIFT SOUTH GYM COLUMNS 2 AND 3
3RD LIFT SOUTH GYM COLUMNS 1 AND 2 ONLY
12/01/2017 REINFORCED MASONRY PRE-GROUT Partial Approval TOP OUT GYM
3RD LIFT STAGE NORTH WALL
11/29/2017 REINFORCED MASONRY PRE-GROUT Partial Approval 4TH LIFT KITCHEN
3RD LIFT STAGE
GYM NORTH WALL TO PLATE HEIGHT ONLY
GYM SOUTH AND WEST WALLS TOP OUT ONLY
11/28/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CANCELED
11/27/2017 REINFORCED MASONRY PRE-GROUT Partial Approval gym south wall 32'-0" height
stage east and west walls 3rd lift only
11/22/2017 REINFORCED MASONRY PRE-GROUT Partial Approval GYM NORTH AND SOUTH WALL 28'-0"
2ND LIFT KITCHEN ONLY
11/20/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection cancelled
11/20/2017 REINFORCED MASONRY PRE-GROUT Partial Approval GYM NORTH AND SOUTH WALLS 24'-4" LIFT ONLY
GYM WEST WALL 28'-0" LIFT ONLY
11/16/2017 REINFORCED MASONRY PRE-GROUT Partial Approval GYM SOUTH WALL 4TH LIFT
GYM WEST WALL 5TH LIFT
GYM NORTH WALL 4TH LIFT
11/15/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CANCELED
11/14/2017 REINFORCED MASONRY PRE-GROUT Partial Approval 4TH LIFT GYM WEST WALL
3RD LIFT GYM NORTH WALL
1ST LIFT RMS 3001, 3005, 3006 AND 3008 ONLY
TOP OUT ELEVATOR SHAFT
11/13/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CANCELED
11/09/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CANCELED
11/08/2017 REINFORCED MASONRY PRE-GROUT Partial Approval 5TH LIFT ELEVATOR SHAFT. GYM WALLS 1ST LIFT NORTH WALL; 2ND LIFT SOUTH AND WEST.
11/07/2017 REINFORCED MASONRY PRE-GROUT Partial Approval TOP OUT EAST BUILDING ONLY
4' LIFT NORTH WALL WEST OF STAGE ONLY
11/06/2017 REINFORCED MASONRY PRE-GROUT Partial Approval 4TH LIFT ELEVATOR
STAIRWELL INTERIOR WALL TOP OUT WITH WEEPS
PARAPET WALL AT ROOM 3208,3206 AND 3204 ONLY
11/03/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection WORK NOT COMPLETE
11/02/2017 REINFORCED MASONRY PRE-GROUT Partial Approval 28'-4" LIFT RMS 3200 NORTH WALL3014,3201,3205,3207,STAIRWELL EXT. WALLS,3210,3206,3204 AND 3200 EAST WALL ONLY
3RD LIFT INTERIOR STAIRWELL WALL ONLY
11/01/2017 REINFORCED MASONRY PRE-GROUT Partial Approval 4th lift east,south,werst walls ok
elevator and stair at 3rd
11/01/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CANCELED
10/31/2017 REINFORCED MASONRY PRE-GROUT Partial Approval 23'-4" LIFT EXTERIOR WALLS RMS 3009,3010,3014,3016,STAIRWELL,3022,3021,3018,AND3015 ONLY
10/30/2017 REINFORCED MASONRY PRE-GROUT Partial Approval GYMNASIUM EAST AND NORTH WALLS 1ST LIFT ONLY
10/27/2017 REINFORCED MASONRY PRE-GROUT Partial Approval west wall 3rd lift, north and east 4th lift, s.w. 3rd lift
10/24/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection NO WORK DONE
10/23/2017 REINFORCED MASONRY PRE-GROUT Partial Approval EXTERIOR NORTH WALL 3RD LIFT/ EXTERIOR EAST WALL3RD LIFT
EXTERIOR STAIRWELL WALLS ONLY AND 2ND LIFT NORTH STAIRWELL WALL
2ND LIFT ELEVATOR ONLY
EAST AREAS ONLY
10/18/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection WORK NOT COMPLETE
10/17/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection no work
10/17/2017 REINFORCED MASONRY PRE-GROUT Partial Approval 2ND LIFT PER 10 / 11 INSPECTION
RMS 3009,3010,3014,3015,3016,3022,3021,3018 AND STAIRWELL WALL ONLY
ELEVATOR 1ST LIFT ONLY
10/13/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection WORK NOT COMPLETE
10/11/2017 REINFORCED MASONRY PRE-GROUT Partial Approval 4' LIFT ONLY EXTERIOR WALLS ROOMS 3009, 3010, 3014, 3016, 3022, 3021, 3018 AND STAIRWELL WALLSONLY
10/10/2017 REINFORCED MASONRY PRE-GROUT Not ready for Inspection WORK NOT COMPLETE