Permit: T17CM02460

Parcel: 116300390

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T17CM02460

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/29/2017 FRAMING Approved
12/28/2017 FRAMING Denied 1 shim bearing headers 2 install diamond mesh on horizontal surfaces greater than 12" 3 pancake boxes at garage overfilled 4 ground metal box atbreakfast nook 5 bond spa motor 6 provide min 12" from can light to pex in bath 3 7 trap arm in laundry overlength 8 provide gas gauge with 1/10th pound increments 9 provide insulation shield on fireplace vent
12/13/2017 FRAMING Denied PROVIDE STAMPED APPROVED TRUSS CALCS
PROVIDE AS BUILTDETAIL 6/S31 GARAGE SHEQR WALL NORTH OR BUILD TO PLAN
SECURE AB"S THROUGHOUT
PROVIDE FIRE STOP AT FIRE PLACE PER SPECS
11/28/2017 FRAMING Not ready for Inspection LATHE PRIOR
10/05/2017 FRAMING Not ready for Inspection WITH INTERMEDIATES