Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T17CM02198
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/27/2017 | BUILDING - FINAL | Approved | ||
07/25/2017 | BUILDING - FINAL | Not ready for Inspection | Call for inspection of all required inspections on permit card. ID electrical panel for no water bond. Seal lineset insulation. Replace damaged clean-out plugs; a machine screw is required with tapped plug. Seal all threaded opennings of DWV system. Solvent cement clean-out adaptor fittings. |
|
07/21/2017 | BUILDING - FINAL | Denied | complete dishwasher high loop, run t + p line in downward pitch, complete all required appliances. |