Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T17CM02144
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/16/2017 | BUILDING - FINAL | Approved | ||
| 06/14/2017 | BUILDING - FINAL | Denied | 1. SHEETROCK SCREWS CANNOT BE USED IN SIMPSON HARDWARE. SIMPSON MAKES SCREWS YOU CAN USE. 2. NOTCHED REAFTERS ARE NOT ACCEPTABLE. PROPERLY SIZED JOIST HANGERS CAN BE USED, OR REPLACE THE RAFTERS. 3. WHAT IS UNDER THE ROOF SHINGLES? ROOF PITCH IS TOO SHALLOW FOR SHINGLES. |