Permit: T17CM01928

Parcel: 121091980

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
12/08/2017 BUILDING - FINAL Approved
10/06/2017 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999
1- SHALL SECURE THE LIQUID TIGHT ELECTRICAL WHIP OF THE COOLER.
2- SHALL PAINT ALL VENTS THRU ROOF WITH A LAYTEX BASE PAINT.
3-SHALL PROVIDE HOSE BIB VACUUM BREAKERS.
4- SHALL PROVIDE WATER HAMMER ARRESTORS AT THE LAUNDRY WATER SUPPLY.
5- SHALL EXTEND AND TERMINATE THE WATER HEATER T & P DRAIN TO DAYLIGHT AND TERMINATE 6 INCHES ABOVE SUB GRADE.
6- SHALL PROVIDE SMOKE DETECTORS WITH FRESH BATTERIES IN ALL BEDROOMS AND HALLWAY.
7- SHALL PROVIDE A CARBON MONOXCIDE DETECTYOR AND LOCATE IT IN THE HALLWAY.
8- SHALL LABEL THE DEAD FRONT PANEL IN SUB PANEL FOR ALL CIRCUIT BREAKERS.
9- SHALL SECURE THE RECEPTICAL OUTLETS AT KITCHEN COUNTER.
10- SHALL PROVIDE GFCI RECEPTICAL IN BATHROOM.
11- SHALL BOND THE GAS LINE.
12- SHALL PROPERLY INSTALL THE DRYER ELECTRICAL OUTLET.
13- SHALL PROVIDE A COVER TRIM PLATE FOR THE GANG RECEPTICAL OUTLET IN THE LAUNDRY ROOM.

*
09/28/2017 BUILDING - FINAL Not ready for Inspection CANCELED BY CONTRACTOR.
09/27/2017 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*