Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T17CM01820
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/10/2017 | PLUMBING - FINAL | Approved | 1- BLDG. FINAL IS OKAY FOR C. OF O. PENDING FIRE APPROVAL. | |
04/06/2017 | PLUMBING - FINAL | Denied | 1- SHALL PROVIDE AN OPEN FRONT SEAT FOR THE WATER CLOSET. 2- SHALL PROVIDE A TEMPERING VALVE AS PER PLAN FOR THE LAVATORY. 3- SHALL LOCATE THE WATER CLOSET 16" TO 18" TO THE CENTER OF WATER CLOSET FOR SIDE WALL CLEARANCE. 4- SHALL LOCATE THE TOP OF THE FLOOD RIM LEVEL OF LAVATORY 34" A.F.F MAX. 5- SHALL LOCATE THE TOILET PAPER DISPECSER MIN. 24" FROM THE REAR WALL. 6- SHALL PROVIDE AN EXPANSION TANK AT THE WATER HEATER. 7- SHALL PROVIDE THE REQUIRED SIGNAGE FOR THE TOILET ROOM AS PER ICC A117.1- 2009. 8- SHALL PROVIDE A ACCESIBLE DOOR HANDLE ON THE TOILET ROOM DOOR. 9- SHALL LOCATE THE GRAB BARS MAX 36" A.F.F. TO THE TOP OF GRAB BARS |