Permit: T17CM01798

Parcel: 137082380

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
07/21/2017 FRAMING Approved
07/20/2017 FRAMING Not ready for Inspection 1- trusses bearing at non bearing points
2- H-2.5 not properly installed through out
3- provide engineers truss report
07/06/2017 FRAMING Denied CHARRED TRUSSES AND FRAMING MEMBERS WITHIN THE STRUCTURE. PROVIDE AN ENGINEERS LETTER VERIFYING MEMBERS ARE NOT COMPROMISED OR REPLACE THEM. SEAL TOP PLATE AT FURRED OUT WALL FOR FIRE BLOCKING. ADD BLOCKING UNDER TRUSS AT BACK SCREEN DOOR HEADER TO COMPLETE THE CORRECT LOAD TRANSFER TO THE EARTH BELOW.
07/03/2017 FRAMING Not ready for Inspection LATHE PRIOR