Permit: T17CM01655

Parcel: 133250580


Addresses:

8611 E 3RD ST

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
03/20/2017 PLUMBING - FINAL Approved 1- ALL CORRECTIONS HAVE BEEN MADE.
CLEAR GAS METER.
03/08/2017 PLUMBING - FINAL Denied 1- SHALL ATTACH THE WATER HEATER VENT DRAFT COLLAR TO THE WATER HEATER AND VENT CONNECTOR.
2- THE GAS BOND SHALL BE CONNECTED TO THE GROUNDING SYSTEM OF THE SERVICE PANEL.
03/03/2017 PLUMBING - FINAL Denied 1- SHALL BOND THE GAS LINE.
2-SHALL REMOVE THE FLEX CONNECTOR ON THE WATER HEATER T & P DRAIN AND ELIMINATE THE TRAP WATER IN THE DRAIN.
3- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR AND LOCATE IT NEAR THE GAS APPLIANCES.
4- SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT ON WATER HEATER FLU VENT AND FURNACE FLU VENT.
5- SHALL PROVIDE A (1") CLERANCE AROUND THE WATER HEATER FLU VENT THRU THE CEILING.
03/02/2017 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*