Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/20/2017 | PLUMBING - FINAL | Approved | 1- ALL CORRECTIONS HAVE BEEN MADE. CLEAR GAS METER. |
|
| 03/08/2017 | PLUMBING - FINAL | Denied | 1- SHALL ATTACH THE WATER HEATER VENT DRAFT COLLAR TO THE WATER HEATER AND VENT CONNECTOR. 2- THE GAS BOND SHALL BE CONNECTED TO THE GROUNDING SYSTEM OF THE SERVICE PANEL. |
|
| 03/03/2017 | PLUMBING - FINAL | Denied | 1- SHALL BOND THE GAS LINE. 2-SHALL REMOVE THE FLEX CONNECTOR ON THE WATER HEATER T & P DRAIN AND ELIMINATE THE TRAP WATER IN THE DRAIN. 3- SHALL PROVIDE A CARBON MONOXCIDE DETECTOR AND LOCATE IT NEAR THE GAS APPLIANCES. 4- SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT ON WATER HEATER FLU VENT AND FURNACE FLU VENT. 5- SHALL PROVIDE A (1") CLERANCE AROUND THE WATER HEATER FLU VENT THRU THE CEILING. |
|
| 03/02/2017 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* |