Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T17CM01406
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/02/2017 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
02/23/2017 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection 1- GAS PRESSURE TEST PROVIDED. 2- GAS BOND PROVIDED. 3-SHALL PROVIDE A CARBON MONOXCIDE DETECTOR. 4- SHALL PROVIDE (3) SHEET METAL SCREWS PER JOINT ON THE WATER HEATER FLU VENT CONNECTOR. 5 SHALL REMOVE THE FLEX CONNECTOR ON THE WATER HEATER T & P DRAIN. 6- SHALL SECURE THE GAS LINE IN THE MECH. ROOM. 7- SHALL HARD PIPE THE GAS LINE SUPPLY INTO THE BBQ CABINET WALL. 8- GAS METER CLEARED. 3- |