Permit: T17CM00897

Parcel: 205942250

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T17CM00897

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/28/2017 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
04/25/2017 MECHANICAL - INTERMEDIATE Partial Approval
04/25/2017 MECHANICAL - INTERMEDIATE Partial Approval TIGHTEN NUTS ON BOTTOM PLATE. GAS PIPE CRUSHED CAN LITE AT STAIRS. SECURE WIRES MBR LID. WIRE UNDER FLOOR TRUSS IN DEN. NAIL STOPS THROUGHOUT. PEX AT LEAST 21 INCH FROM BVENT. SECURE PEX EVERY 32 INCHES. SUPPORT ABS EVERY 4 FEET, MANY STRAPS LOOSE.PEX BELOW FLOOR JOISTS IN GARAGE. NO ABS WATER TEST.SECURE TOILET RING IN POWDER ROOM. NAIL STOPS THRUOUT. GAS TEST OKAY, SECURE GASLINE AT STOVE. SUPPORT PVC EVERY 4 FEET HORIZ.