Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/17/2017 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 02/16/2017 | PLUMBING - ROUGH, SOIL | Denied | stll have back pitch at wc, and rocks on pex under slab; sleeve, or shade tubing, also shade or protect yard line |
|
| 02/15/2017 | PLUMBING - ROUGH, SOIL | Denied | remove rocks from pipe and tube, support and shade w cln fill connnect new tracer wire to existing wire w gel wire nut correct slope at wc island loop vent shown on plan at ks,provide doc for change |