Permit: T17CM00863

Parcel: 141387700

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T17CM00863

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
05/09/2017 FRAMING Approved
05/05/2017 FRAMING Not ready for Inspection
05/03/2017 FRAMING Denied correct over notch of ext wall top plates on both levels and for ABS as well as line set.

softener drain termination mst be plumb over indirect waste receptor.

Horizontal section of metal dryer uct requires a metal duct strap, or rivet both joints.
05/02/2017 FRAMING Denied 1.LARGE PROTECTIVE BANG PLATES ARE NOT STRUCTURALLY RE-INFORCING. FOR OVER BORES AND OVER NOTCHES, FHA STRAPS FULLY NAILED ARE REQUIRED.
05/01/2017 FRAMING Denied top plate repair