Permit: T17CM00799

Parcel: 136254110

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
06/06/2017 BUILDING - FINAL Approved
06/01/2017 BUILDING - FINAL Denied Install label specified on plan; do not relocate backfed breaker.
Provide 3' clearance on on side of eve to ridge, protect all exposed raceways
05/24/2017 BUILDING - FINAL Denied Provide:
City approved plans for inspections,
3' clear as required per IFC 605.11
labels on backfed breakers, and DC raceway or J-boxes.
Land and torque conductors, secure grounding conductor to wall independet of raceway with approved clamps. Protect and ecure all conductors. remove paint under field installed grounding lugs.
05/19/2017 BUILDING - FINAL Not ready for Inspection Support wires, cannot lay on roof deck. Provide roof access. Label all equipment, provide plans, incomplete inspection.