Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T17CM00673
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/31/2018 | REINFORCED MASONRY PRE-GROUT | Approved | ||
| 07/30/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 3RD LIFT SOUTH WALL 12'-8" LIFT |
|
| 07/27/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 2nd lift at south 9' section ok | |
| 07/25/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift at south wall 9' section | |
| 06/20/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | east screen wall top out ok | |
| 06/19/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | ||
| 06/15/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift eastside screen wall ok | |
| 06/14/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
| 05/04/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TOP OUT SCREEN WALL WEST | |
| 05/02/2018 | REINFORCED MASONRY PRE-GROUT | Denied | verts to extend through bond beam | |
| 04/23/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
| 04/20/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift S.W. sitewall ok | |
| 04/19/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
| 04/18/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | top out at radius and trash room ok | |
| 04/17/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
| 04/16/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | east trash entrance 3rd lift ok | |
| 04/12/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
| 04/11/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift east radius, 2nd lift trash east entrance | |
| 12/07/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | top out at pump room ok | |
| 12/05/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift 2nd level pump room | |
| 11/07/2017 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
| 11/06/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | pump room bond beam lower level west | |
| 11/03/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | top out ok except pump room | |
| 11/02/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | top out south wall CL 4 west | |
| 11/01/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 2nd lift ok | |
| 10/30/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LOWER LEVEL 2ND LIFT GRID LINE 1 FROM E TO F 3RD LIFT GRID LINE E.5 FROM 1 TO 2 3RD LIFT GRID LINE 2.2 FROM E.75 TO F TOP OUT STAIRWELL WALL 3RD LIFT GRID LINE F FROM 2.2 TO 3 3RD LIFT RADIUS WALL 2ND LIFT GRID LINE D.7 FROM 5 TO 6 WITH CONDUIT FOR LIGHTING ALL AREAS |
|
| 10/27/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift ok | |
| 10/24/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | stem wall bond beam ok |