Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T17CM00673
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/31/2018 | REINFORCED MASONRY PRE-GROUT | Approved | ||
07/30/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 3RD LIFT SOUTH WALL 12'-8" LIFT |
|
07/27/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 2nd lift at south 9' section ok | |
07/25/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift at south wall 9' section | |
06/20/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | east screen wall top out ok | |
06/19/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | ||
06/15/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift eastside screen wall ok | |
06/14/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
05/04/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TOP OUT SCREEN WALL WEST | |
05/02/2018 | REINFORCED MASONRY PRE-GROUT | Denied | verts to extend through bond beam | |
04/23/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
04/20/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift S.W. sitewall ok | |
04/19/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
04/18/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | top out at radius and trash room ok | |
04/17/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
04/16/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | east trash entrance 3rd lift ok | |
04/12/2018 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
04/11/2018 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift east radius, 2nd lift trash east entrance | |
12/07/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | top out at pump room ok | |
12/05/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift 2nd level pump room | |
11/07/2017 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | no work | |
11/06/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | pump room bond beam lower level west | |
11/03/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | top out ok except pump room | |
11/02/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | top out south wall CL 4 west | |
11/01/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 2nd lift ok | |
10/30/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | LOWER LEVEL 2ND LIFT GRID LINE 1 FROM E TO F 3RD LIFT GRID LINE E.5 FROM 1 TO 2 3RD LIFT GRID LINE 2.2 FROM E.75 TO F TOP OUT STAIRWELL WALL 3RD LIFT GRID LINE F FROM 2.2 TO 3 3RD LIFT RADIUS WALL 2ND LIFT GRID LINE D.7 FROM 5 TO 6 WITH CONDUIT FOR LIGHTING ALL AREAS |
|
10/27/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift ok | |
10/24/2017 | REINFORCED MASONRY PRE-GROUT | Partial Approval | stem wall bond beam ok |